Mobile Tower Radiation Meter

With the increase of cell phone towers and the health hazards that accompany them, it has become imperative for people and societies at large to understand and evaluate the radiation, field levels around them, its origins, its effects and concerns along with an action plan to reduce or maintain the level to safe limits.

Our Services includes:

Sales: We provide the latest equipment available for measuring RF/EMF radiation levels. It is simple to use and operate.

Surveying/Evaluation: We conduct testing and site assessments for individuals, residential/commercial complexes, schools, building managers where cell phone towers have been installed to measure the radiation exposure and measure EMF levels and its corresponding health effects which would be provided in form of a report.

If new antennas or towers are planned for your location, our survey can be used to establish a baseline RF level for later comparison (before and after testing). Follow-up readings are provided at substantially reduced cost compared to the initial survey.

PRODUCT: EMF Detector/Meter for Mobile Tower Radiation

AI195

This Three-Axis RF Field Strength Meter is designed for measuring and monitoring radio frequency electromagnetic field strength. The meter is calibrated precisely over the frequency range of 50MHz ~ 3.5GHz.

It is used to indicate electromagnetic pollution generated artificially, and wherever a voltage or a current, electric (E) and magnetic (H) fields arise. All types of radio broadcasting, mobile towers and TV transmitters produce electromagnetic fields, and they also arise in industry, business and the home, where they affect our health even if our sense organs perceive nothing.



Specification

Measurement Ranges 38mv to 11v/m Display 3-3/4 digits maximum reading 3999
Display 3-3/4 digits maximum reading 3999
Frequency Range 50MHz ~ 3.5GHz
Measurement Units mV/m, V/m, µA/m, mA/m, µW/m2, mW/m2, µW/cm2
Display Resolution 0.1mV/m, 0.1µA/m, 0.001µW/m2, 0.001µW/cm2
Manual Data Memory Read Storage: 200 Data Sets.
Alarm Function Adjustable Threshold with ON/ OFF
Memory Recall Records Maximum & AVG
Calibration Factor CAL Adjustable
Sampling Time 2.5 times per second.
Operating Temperature & Humidity 0 to 50ºC (32ºF to 122ºF). Max. 80% RH.
Power Supply 9V battery (NEDA 1604 IEC 6F 22 JIS 006P)*1
Battery Life Approx. 50 hr.

FEATURES:

  • The meter is a broadband device for monitoring high frequency radiation in the range from 50MHz to 3.5GHz.
  • The non-directional electric field antenna and high sensitivity also allow measurements of electric field strength in TEM cells and absorber rooms.
  • Configurable alarm threshold and memory function.
  • High dynamic range due to three-channel digital results processing.
  • Easy and safe to use.
  • At high frequencies, the power density is of particular significance. It provides a measure of the power absorbed by a person exposed to the field. This power level must be kept as low as possible at high frequencies.
  • Non-directional (isotropic) measurement with three-channel measurement sensor.

FREQUENCY RESPONSE:

  • Sensor taking into account the typical CAL factor:
    • ± 2.4dB (50MHz to 1.9 GHz)
    • ± 1.0dB (1.9GHz to 3.5 GHz)
  • Isotropy deviation. Typically ± 1.0dB (f 2.45GHz)
  • Overload limit: 0.42 mW/cm² (11 V/m) per axis.
  • Overload limit: (0 to 50°C): ±0.2dB.

Brochure

Mobile Tower Radiation FAQ